UV STERLIZER LIGHT - XSY3003

  • AC110V / AC200-240V
  • 245nm UVC wave lenght, Ozone-free
  • High-quality UV lamp kills 99% of bacteria & viruses
  • Quartz sleeve is resistant to damage, leakage, and moisture
  • Built-in timer can be set to 15/30/60 minutes
  • 15-second work delay to ensure people and pets leave
  • Child lock avoids the danger caused by children's curiosity
  • 1 year warranty

Specification
ModelXSY3003
Power36W
VoltageAC110V/200-240V, 50/60Hz
UV lightUVC
UV Wavelength245nm
UV Output120±3μW/cm²
Disinfection area1㎡-50㎡
Timer15/30/60 minutes
Child lockYes
Control methodTouch
Wire length1.6m
MaterialAluminum alloy
Work temperature-10°C to 40°C
Tube lifespan8,000hrs
SizeØ197*445mm
ColorRose gold / Silver
Contact
details
uv light operation instruction

Operation instructions

1. Touch the function switch once, the power indicator light will be on until the end of disinfection ( If you need to close in advance, long-press the switch).
2. Then every time you touch the function switch, the time will cycle between 15-30-60 minutes and the corresponding indicator flashes.
3. 2 seconds after the selected disinfection time, the buzzer will beep for 1-2 seconds, the red indicator light of corresponding disinfection time will be on for, and after a delay of 15 seconds, the control board will supply power to the disinfection lamp to start disinfection.
4. Shortly before the disinfection is completed, the short beep counts down for 10 seconds, the control panel output is powered off and the disinfection ends, and all the indicators are off;
5. Every time you touch the function switch, whether it is a light touch or a long press, it is accompanied by a short buzzer;
6. The default setting is that all indicators are off and the time is not selected;
7. a. Child lock function: When the power indicator light is in the long bright state, touch the function switch 6 times within 5 seconds to lock the disinfection lamp. All functions cannot work.
b. The child lock and the power indicator light are on, and the whole lamp is in the standby state. Within 10 seconds of delay after locking, tap again 6 times within 5 seconds to unlock.
c. The child lock function has a memory function. When the child lock is not turned off but the control board is powered off, the control board is still locked after power is supplied again.

uv light operation instruction

Operation instructions

1. Touch the function switch once, the power indicator light will be on until the end of disinfection ( If you need to close in advance, long-press the switch).
2. Then every time you touch the function switch, the time will cycle between 15-30-60 minutes and the corresponding indicator flashes.
3. 2 seconds after the selected disinfection time, the buzzer will beep for 1-2 seconds, the red indicator light of corresponding disinfection time will be on for, and after a delay of 15 seconds, the control board will supply power to the disinfection lamp to start disinfection.
4. Shortly before the disinfection is completed, the short beep counts down for 10 seconds, the control panel output is powered off and the disinfection ends, and all the indicators are off;
5. Every time you touch the function switch, whether it is a light touch or a long press, it is accompanied by a short buzzer;
6. The default setting is that all indicators are off and the time is not selected;
7. a. Child lock function: When the power indicator light is in the long bright state, touch the function switch 6 times within 5 seconds to lock the disinfection lamp. All functions cannot work.
b. The child lock and the power indicator light are on, and the whole lamp is in the standby state. Within 10 seconds of delay after locking, tap again 6 times within 5 seconds to unlock.
c. The child lock function has a memory function. When the child lock is not turned off but the control board is powered off, the control board is still locked after power is supplied again.

Dimension

xsy3003 size
ModelSizeN.WN.W
XSY3003Ø197*445mm1.4kg1.9kg

Applications

Residence ( Bedroom, Bathroom, Kitchen, Parlor, etc ), Office, Items cleaning.

bedroom

Bedroom

kitchen

Kitchen

parlor

Parlor

office

Office

CAUTION: RISK OF INJURY
1. Prolonged exposure to UV rays can burn human and animal skin, do damage to the human eye.
2. Pay attention to indoor precious calligraphy obscured to prevent prolonged ultraviolet radiation oxidation discoloration.
3. There is the killing effect of ultraviolet radiation on organic cells. Do not put long-term exposure to pets and plants.
4. During the period of working: people, animals, and plants must leave the scene to avoid burning.
5. Do not irradiate the food; when disinfecting the bed, put the lamp on the bedside cabinet or the table.
6. After working: It needs to be ventilated for more than 60 minutes.
7. Since packaging materials may cause harm to children, they should be disposed of and destroyed in time.

Contact us to get a free quotation!

Related fixtures

Scroll to Top